6 ROGUE TERRAIN OFF GRID POWER SUPPLY ENCLOSURE
SPECIFICATIONS
CHARGE CONTROLLER – 5 AMP VERSION
Battery Voltage: 12 VDC
Maximum Load Current: 5 Amps
Self-Consumption: Not Charging ~400 uA
Charging ~2 mA
Fast / Compensation Mode ON Voltage: ~12.8 VDC
Fast / Compensation Mode OFF Voltage: ~14.7 VDC
Float Mode Voltage: ~14.1 VDC
Temperature Compensation: -3.3mV/ Degree C. / Cell
Operating Temperature: -40 Degrees C. to +60 Degrees C.
CHARGE CONTROLLER – 10 AMP VERSION
Battery Voltage: 12 VDC
Maximum Load Current: 10 Amps
Self-Consumption: Not Charging ~400 uA
Charging ~1.8 mA
Fast / Compensation Mode ON Voltage: ~12.8 VDC
Fast / Compensation Mode OFF Voltage: ~14.7 VDC
Float Mode Voltage: ~14.1 VDC
Temperature Compensation: -3.3mV/ Degree C. / Cell
Operating Temperature: -40 Degrees C. to +60 Degrees C.
LOW VOLTAGE DISCONNECT
Battery Voltage: 12 VDC
Maximum Load Current: 15 Amps
Disconnect Increments: Every 0.5V from 9.0V to 11.5V
Reconnect Sequence: Battery Voltage Exceeds Selected Disconnect Voltage
by 1V.
Self-Consumption: Battery Voltage Above Disconnect Threshold ~ 2 mA
Battery Voltage Below Disconnect Threshold ~ 550 uA